Brand Name : Iflow

Model Number : 2000F

Certification : ISO9001, CE

Place of Origin : China

MOQ : negotiable

Price : negotiable

Payment Terms : T/T, L/C

Supply Ability : 2200000 units per year

Delivery Time : 4-6 weeks

Packaging Details : wooden case pluse pallet

Type : Ultraonsic flow meter

Pipe diameter : 2" - 48"

Application : sewage, waste water, effluent

Electrode : 316L / Hasteeloy-C / Ti / Ta / Pt100

Measure : flow and heat

Protection : IP68

Accuracy : 0.25% , 0.5%

Connect : flange port

Contact Now

Ultrasonic sewage flow meter, transit time, clamp on transducer DN50-700

Product Description:

The ultrasonic water meter are with built in batch controller and time accumulator. It has extremely low power consumption, stable and reliable performance in long term. All the wet part protection is IP68. The UFM is widely used in municipal water supply, water resource management, industrial water supply, agriculture, irrigation and gardening.

Application industries:

Non contact type water flow meter, the industries in order of higher to lower are oil and gas, water and wastewater, power, chemical, food and beverage, pharmaceutical, metals and mining, and pulp and paper.

Features

  • Superior hydraulic design, no moving parts, zero wear, eliminate maintenance
  • Advanced ultrasonic technology for precise and ultra reliable metering
  • Extremely wide turndown ratio (R=500)
  • Excellent long-term stability and reliability
  • Extremely sensitive and accurate in low flow
  • Battery powered – above 10 years or up to 20 years life expectancy
  • Made with highly durable materials - epoxy coated cast iron,
  • Cast iron, cast steel, stainless, various construction material available for medicine and health as well as sea water and corrosive fluid metering
  • Ruggedized construction - Fully submersible design (IP68)

Parameters

Liquid media: water, sewage, seawater, effulent, municipal tap water, etc.

Work temperature: 0.1 - 30℃

Environment termpreature: -10 - 45℃

Humidity: <100% RH

Operate pressure: 1.6 Mpa / 2.5 Mpa

Upstream sensitivity: U3

Down stream sensitivity: D0

Climatic and mechanical: class C

EMC compativility class: class E2

Communication: RS485 / USART / Infrared

Signal output: Dual way OCT pulse / TTL pulse / single way 4-20mA

Power supply: lithium battery, 3.6V / 19Ah or DC8-36V

Protection: IP68

Digital display Multi line 9 digital accumulated flow, 4 digital instant flow

Data storage: EEPROME / Flash, last 512 days accumulative flow

Measuring cycle: every second, Verification: 4 times / second

Standard: ISO4064, GBT 778-2007

Product overview

  • Enclosure protection IP68
  • Built in batch controller and time accumulator
  • Heat measurement for refigeration and air conditioning system
  • Double beam ultrasonic sensor for high accuracy
  • No moving parts, no rotation

Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700

Display and operation

  • LCD display of instantaneous flow, accumulative flow, time
  • Bi-directional flow measurement
  • Display in different units, volume: cubic meter, ft, gallon, liter & velocity: m3/h, GPM, LPM.
  • Touch key panel
  • Infrared communication interface

Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700

Communication and signal output

RS485 OCT1 (open collector output 1)
M-BUS OCT2 (open collector output 2)
DC8-36V C1 (TTL level pulse output 1)
Two-way 4-20mA output C2 (TTL level pulse output 2)

Material

DN15-DN40 Single channel ultrasonic water meter (copper)

DN50-DN40 Dual channel bulk ultrasonic water meter (cast iron)

DN200-DN300 Dual channel large ultrasonic water meter (welded carbon steel)

Flow range

Nominal D R Flow (m3/h)
Starting flow Minimal flow (Q1) Transitional flow (Q2) Normal flow (Q3) Overload flow (Q4)
DN15 200 0.003 0.0125 0.020 2.500 3.125
DN20 200 0.0035 0.016 0.026 3.200 4.000
DN25 200 0.007 0.020 0.032 4.000 5.000
DN32 200 0.010 0.032 0.050 6.300 7.875
DN40 200 0.015 0.100 0.160 20.000 25.000
DN50 100 0.030 0.400 0.640 40.000 50.000
DN65 100 0.059 0.630 1.008 63.000 78.750
DN80 100 0.064 1.000 1.600 100.000 125.000
DN100 100 0.094 1.600 2.560 160.000 200.000
DN125 100 0.120 2.000 3.200 200.000 250.000
DN150 100 0.270 2.500 4.000 250.000 312.500
DN200 100 0.315 4.000 6.400 400.00 500.00
DN250 100 0.508 4.000 6.400 400.00 500.00
DN300 100 0.770 6.300 10.080 630.00 787.500

Competitive Advantage:

  • Compliance to international standards: ISO 4064-2005 , GBT 778.1-2007
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Product Tags:

sewer flow meter

      

flow meter for sewage water

      
Best Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700 wholesale

Ip68 Ultrasonic Liquid Flow Meter Transit Time With Clamp On Transducer Dn50-700 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai I Fluid Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0